CORC  > 清华大学
Removal characteristics of organic pollutants in sewage treatment by a pre-coagulation, ozonation and ozone/hydrogen peroxide process
Mizuno, Tadao ; Tsuno, Hiroshi ; Yamada, Harumi ; Takeshima, Daisuke
2010-05-11 ; 2010-05-11
关键词organic compounds sewage treatment ozonation ozone/hydrogen peroxide process pre-coagulation advanced oxidation HYDROGEN-PEROXIDE WASTE-WATER OXIDATION Engineering, Environmental Environmental Sciences
中文摘要The applicability of a sequential process of ozonation and ozone/hydrogen peroxide process for the removal of soluble organic compounds from a pre-coagulated municipal sewage was examined. 6-25% of initial T-CODCr was removed at the early stage of ozonation before the ratio of consumed ozone to removed T-CODCr dramatically increased. Until dissolved ozone was detected, 0.3 mgO(3)/mgTOC(0) (Initial TOC) of ozone was consumed. When an ozone/hydrogen peroxide process was applied, additional CODCr was removed. And we elucidated that two following findings are important for the better performance of ozone/hydrogen peroxide process; those are to remove readily reactive organic compounds with ozone before the application of ozone/hydrogen peroxide process and to avoid the excess addition of hydrogen peroxide. Based on these two findings, we proposed a sequential process of ozonation and multi-stage ozone/hydrogen peroxide process and the appropriate addition of hydrogen peroxide. T-CODCr, TOC and ATU-BOD5 were reduced to less than 7 mg/L, 6 mgC/L and 5 mg/L, respectively after total treatment time of 79 min. Furthermore, we discussed the transformation of organic compounds and the removal of organic compounds. The removal amount of CODCr and UV254 had good linear relationship until the removal amounts of CODCr and UV254 were 30 mg/L and 0.11 cm(-1), respectively. Therefore UV254 would be useful for an indicator for CODCr removal at the beginning of the treatment. The accumulation of carboxylic acids (formic acid, acetic acid and oxalic acid) was observed. The ratio of carbon concentration of carboxylic acids to TOC remaining was getting higher and reached around 0.5 finally. Removal of TOC was observed with the accumulation of carboxylic acids. When unknown organic compounds (organic compounds except for carboxylic acids) were oxidized, 70% was apparently removed as carbon dioxide and 30% was accumulated as carboxylic acids. A portion of biodegradable organic compounds to whole organic compounds was enhanced as shown by the increase ratio of BOD/CODCr.
语种英语 ; 英语
出版者TAYLOR & FRANCIS INC ; PHILADELPHIA ; 325 CHESTNUT ST, SUITE 800, PHILADELPHIA, PA 19106 USA
内容类型期刊论文
源URL[http://hdl.handle.net/123456789/26407]  
专题清华大学
推荐引用方式
GB/T 7714
Mizuno, Tadao,Tsuno, Hiroshi,Yamada, Harumi,et al. Removal characteristics of organic pollutants in sewage treatment by a pre-coagulation, ozonation and ozone/hydrogen peroxide process[J],2010, 2010.
APA Mizuno, Tadao,Tsuno, Hiroshi,Yamada, Harumi,&Takeshima, Daisuke.(2010).Removal characteristics of organic pollutants in sewage treatment by a pre-coagulation, ozonation and ozone/hydrogen peroxide process..
MLA Mizuno, Tadao,et al."Removal characteristics of organic pollutants in sewage treatment by a pre-coagulation, ozonation and ozone/hydrogen peroxide process".(2010).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace