Parallel analog channels for oversampling scientific CCD camera signal
Qiu Hong-yun ; Liu Yang ; Zhang En-yao ; Sun Li-qun ; Tian Qian
2010-05-10 ; 2010-05-10
关键词Practical Experimental/ CCD image sensors parallel processing signal denoising signal sampling/ parallel analog channels oversampling scientific CCD camera signal noise reduction method noise distribution programmer gain amplifier power supply noise higher AD conversion rate/ B7230G Image sensors B2570H Other field effect integrated circuits B6140 Signal processing and detection
中文摘要A noise reduction method of using multiple identical analog channels to over/sample the CCD signal is investigated experimentally. This method is based on the irrelevant noise characters in each part of the CCD camera's analog channel. The noise distribution in the circuit is tested and the noise improving factors are 1.354 and 1.65 for the two parallel connections and three parallel connections respectively. The improving factor agrees with the theory value. Experiment shows that the improving factor decreases with the increase of the gain of the programmer gain amplifier in the analog channel. This phenomenon and the difference between the experiment value and the theory value of improving factor are analyzed. The power supply noise, higher AD conversion rate and temperature rising are the major factors of the difference.
语种中文 ; 中文
出版者Editorial Board of Journal of Applied Optics ; China
内容类型期刊论文
源URL[http://hdl.handle.net/123456789/24518]  
专题清华大学
推荐引用方式
GB/T 7714
Qiu Hong-yun,Liu Yang,Zhang En-yao,et al. Parallel analog channels for oversampling scientific CCD camera signal[J],2010, 2010.
APA Qiu Hong-yun,Liu Yang,Zhang En-yao,Sun Li-qun,&Tian Qian.(2010).Parallel analog channels for oversampling scientific CCD camera signal..
MLA Qiu Hong-yun,et al."Parallel analog channels for oversampling scientific CCD camera signal".(2010).