CORC  > 清华大学
Characteristics of inhalable particulate matter concentration and size distribution from power plants in China
Yi, Honghong ; Hao, Jiming ; Duan, Lei ; Li, Xinghua ; Guo, Xingming
2010-05-10 ; 2010-05-10
关键词ELECTROSTATIC PRECIPITATOR COLLECTION EFFICIENCY COMBUSTION INCINERATION EMISSIONS SLUDGE HEALTH Engineering, Environmental Environmental Sciences Meteorology & Atmospheric Sciences
中文摘要In this investigation, the collection efficiency of particulate emission control devices (PECDs), particulate matter (PM) emissions, and PM size distribution were determined experimentally at the inlet and outlet of PECDs at five coal-fired power plants. Different boilers, coals, and PECDs are used in these power plants. Measurement in situ was performed by an electrical low-pressure impactor with a sampling system, which consisted of an isokinetic sampler probe, precut cyclone, and two-stage dilution system with a sample line to the instruments. The size distribution was measured over a range from 0.03 to 10 mu m. Before and after all of the PECDs, the particle number size distributions display a bimodal distribution. The PM2.5 fraction emitted to atmosphere includes a significant amount of the mass from the coarse particle mode. The controlled and uncontrolled emission factors of total PM, inhalable PM (PM10), and fine PM P(M-2.5) were obtained. Electrostatic precipitator (ESP) and baghouse total collection efficiencies are 96.38-99.89% and 99.94%, respectively. The minimum collection efficiency of the ESP and the baghouse both appear in the particle size range of 0.1-1 mu m. In this size range, ESP and baghouse collection efficiencies are 85.79-98.6% and 99.54%. Real-time measurement shows that the mass and number concentration of PM,0 will be greatly affected by the operating conditions of the PECDs. The number of emitted particles increases with increasing boiler load level because of higher combustion temperature. During test run periods, the data reproducibility is satisfactory.
语种英语 ; 英语
出版者AIR & WASTE MANAGEMENT ASSOC ; PITTSBURGH ; ONE GATEWAY CENTER, THIRD FL, PITTSBURGH, PA 15222 USA
内容类型期刊论文
源URL[http://hdl.handle.net/123456789/23256]  
专题清华大学
推荐引用方式
GB/T 7714
Yi, Honghong,Hao, Jiming,Duan, Lei,et al. Characteristics of inhalable particulate matter concentration and size distribution from power plants in China[J],2010, 2010.
APA Yi, Honghong,Hao, Jiming,Duan, Lei,Li, Xinghua,&Guo, Xingming.(2010).Characteristics of inhalable particulate matter concentration and size distribution from power plants in China..
MLA Yi, Honghong,et al."Characteristics of inhalable particulate matter concentration and size distribution from power plants in China".(2010).