Hemocompatibility of C-N films fabricated by ion beam assisted deposition | |
Zheng, C.L. ; Cui, F.Z. ; Meng, B. ; Ge, J. ; Liu, D.P. ; Lee, I.-S. | |
2010-05-10 ; 2010-05-10 | |
关键词 | Experimental/ atomic force microscopy Auger electron spectra biomedical materials blood carbon compounds contact angle ion beam assisted deposition surface composition surface roughness X-ray photoelectron spectra/ hemocompatibility biocompatible films ion beam assisted deposition Si(111) wafers surface composition bonding types surface roughness AES X-ray photoelectron spectroscopy XPS atomic force microscopy AFM contact angle dynamic clotting time platelet consumption rate blood compatibility CN Si/ A8770M Biomedical materials A6820 Solid surface structure A6810C Fluid surface energy (surface tension, interface tension, angle of contact, etc.) A7920F Electron-surface impact: Auger emission A7960 Photoemission and photoelectron spectra (condensed matter) A8280P Electron spectroscopy for chemical analysis (photoelectron, Auger spectroscopy, etc.)/ CN/bin C/bin N/bin Si/sur Si/el |
中文摘要 | Biocompatible films have great practical potentialities in biomedical field. They are often used on blood-contacting occasions such as intraluminal metallic stents and artificial heart valves for the purpose of hemocompatibility improvements. In this paper, C-N films were synthesized on Si(111) wafers by means of ion beam assisted deposition (IBAD). Surface composition, bonding types and surface roughness were addressed by AES, X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM). In vitro measurements of contact angle, dynamic clotting time and platelet consumption rate were used to evaluate the blood compatibility of C-N film in comparison with that of NiTi and 316L. The results indicate that the blood compatibility of C-N film is superior to that of NiTi alloy and 316L stainless steel. [All rights reserved Elsevier]. |
语种 | 英语 ; 英语 |
出版者 | Elsevier ; Switzerland |
内容类型 | 期刊论文 |
源URL | [http://hdl.handle.net/123456789/20385] ![]() |
专题 | 清华大学 |
推荐引用方式 GB/T 7714 | Zheng, C.L.,Cui, F.Z.,Meng, B.,et al. Hemocompatibility of C-N films fabricated by ion beam assisted deposition[J],2010, 2010. |
APA | Zheng, C.L.,Cui, F.Z.,Meng, B.,Ge, J.,Liu, D.P.,&Lee, I.-S..(2010).Hemocompatibility of C-N films fabricated by ion beam assisted deposition.. |
MLA | Zheng, C.L.,et al."Hemocompatibility of C-N films fabricated by ion beam assisted deposition".(2010). |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论