High-speed intravascular spectroscopic photoacoustic imaging at 1000 A-lines per second with a 0.9-mm diameter catheter | |
Yan Li; Xiaojing Gong; Chengbo Liu; Riqiang Lin; William Hau; Xiaosong Bai; Liang Song | |
刊名 | JOURNAL OF BIOMEDICAL OPTICS
![]() |
2015 | |
英文摘要 | Intravascular spectroscopic photoacoustic technology can image atherosclerotic plaque composition with high sensitivity and specificity, which is critical for identifying vulnerable plaques. Here, we designed and engineered a catheter of 0.9 mm in diameter for intravascular photoacoustic (IVPA) imaging, smaller than the critical size of 1 mm required for clinical translation. Further, a quasifocusing photoacoustic excitation scheme was developed for thecatheter, producing well-detectable IVPA signals from stents and lipids with a laser energy as low as similar to 30 mu J/pulse. As a result, this design enabled the use of a low-energy, high-repetition rate, ns-pulsed optical parametric oscillator laser for high-speed spectroscopic IVPA imaging at both the 1.2-mu m and 1.7-mu m spectral bands for lipid detection. Specifically, for each wavelength, a 1-kHz IVPA A-line rate was achieved, similar to 100-fold faster than previously reported IVPA systems offering a similar wavelength tuning range. Using the system, spectroscopic IVPA imaging of peri-adventitial adipose tissue from a porcine aorta segment was demonstrated. The significantly improved imaging speed, together with the reduced cathetersize and multi-wavelength spectroscopic imaging ability, suggests that the developed high-speed IVPA technology is of great potential to be further translated for in vivo applications. ( |
收录类别 | SCI |
原文出处 | http://biomedicaloptics.spiedigitallibrary.org/article.aspx?articleid=2352820 |
语种 | 英语 |
内容类型 | 期刊论文 |
源URL | [http://ir.siat.ac.cn:8080/handle/172644/7069] ![]() |
专题 | 深圳先进技术研究院_医工所 |
作者单位 | JOURNAL OF BIOMEDICAL OPTICS |
推荐引用方式 GB/T 7714 | Yan Li,Xiaojing Gong,Chengbo Liu,et al. High-speed intravascular spectroscopic photoacoustic imaging at 1000 A-lines per second with a 0.9-mm diameter catheter[J]. JOURNAL OF BIOMEDICAL OPTICS,2015. |
APA | Yan Li.,Xiaojing Gong.,Chengbo Liu.,Riqiang Lin.,William Hau.,...&Liang Song.(2015).High-speed intravascular spectroscopic photoacoustic imaging at 1000 A-lines per second with a 0.9-mm diameter catheter.JOURNAL OF BIOMEDICAL OPTICS. |
MLA | Yan Li,et al."High-speed intravascular spectroscopic photoacoustic imaging at 1000 A-lines per second with a 0.9-mm diameter catheter".JOURNAL OF BIOMEDICAL OPTICS (2015). |