Image Reconstruction for ECT Based on Extended Sensitivity Matrix
Ye, Jiamin1; Mao, Mingxu1; Wang, Haigang1; Yang, Wuqiang2
刊名IEEE SENSORS JOURNAL
2016-04-15
卷号16期号:8页码:2466-2476
关键词Electrical capacitance tomography iterative algorithm extended sensitivity matrix numerical simulation experimental study
英文摘要Image reconstruction for electrical capacitance tomography (ECT) is usually based on a sensitivity matrix. To reduce the effect of soft-filed property of ECT and enhance the quality of reconstructed images, a new image reconstruction method for ECT based on an extended sensitivity matrix is proposed. The elements used in constructing the sensitivity matrix are a set of block bases instead of each individual pixel. Using the new block basis approach, an iterative algorithm for image reconstruction in ECT is implemented with a 12-electrode square ECT sensor. The performance of the new approach is evaluated according to the simulation and experimental results. Preliminary results show that the image reconstruction based on an extended sensitivity matrix with a suitably designed block basis can improve the image quality and stability compared with the Landweber iteration algorithm based on the conventional one-pixel basis.
WOS标题词Science & Technology ; Technology ; Physical Sciences
类目[WOS]Engineering, Electrical & Electronic ; Instruments & Instrumentation ; Physics, Applied
研究领域[WOS]Engineering ; Instruments & Instrumentation ; Physics
关键词[WOS]ELECTRICAL CAPACITANCE TOMOGRAPHY ; FLUIDIZED-BEDS ; SENSORS ; FLOW ; ALGORITHMS ; SOLIDS ; DESIGN
收录类别SCI
语种英语
WOS记录号WOS:000372419100035
内容类型期刊论文
源URL[http://ir.etp.ac.cn/handle/311046/112446]  
专题工程热物理研究所_中国科学院工程热物理所(论文库)_期刊论文(SCI)
作者单位1.Chinese Acad Sci, Inst Engn Thermophys, Beijing 100190, Peoples R China
2.Univ Manchester, Sch Elect & Elect Engn, Manchester M13 9PL, Lancs, England
推荐引用方式
GB/T 7714
Ye, Jiamin,Mao, Mingxu,Wang, Haigang,et al. Image Reconstruction for ECT Based on Extended Sensitivity Matrix[J]. IEEE SENSORS JOURNAL,2016,16(8):2466-2476.
APA Ye, Jiamin,Mao, Mingxu,Wang, Haigang,&Yang, Wuqiang.(2016).Image Reconstruction for ECT Based on Extended Sensitivity Matrix.IEEE SENSORS JOURNAL,16(8),2466-2476.
MLA Ye, Jiamin,et al."Image Reconstruction for ECT Based on Extended Sensitivity Matrix".IEEE SENSORS JOURNAL 16.8(2016):2466-2476.