基于傅里叶变换的差分吸收光谱法测量NH_3和SO_2浓度的实验研究 | |
郁敏捷; 刘铭晖; 董作人; 孙延光; 蔡海文; 魏芳 | |
刊名 | 中国激光
![]() |
2015 | |
卷号 | 42期号:9页码:915001 |
其他题名 | Study on Measuring Concentration of Ammonia and Sulphur Dioxide by Differential Optical Absorption Spectrometry Based on Fast Fourier Transform |
通讯作者 | Yu Minjie, Shanghai Key Laboratory of All Solid-State Laser and Applied Techniques, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China. ; Liu Minghui, Shanghai Key Laboratory of All Solid-State Laser and Applied Techniques, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China. ; Dong Zuoren, Shanghai Key Laboratory of All Solid-State Laser and Applied Techniques, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China. ; Sun Yanguang, Shanghai Key Laboratory of All Solid-State Laser and Applied Techniques, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China. ; Cai Haiwen, Shanghai Key Laboratory of All Solid-State Laser and Applied Techniques, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China. ; Wei Fang, Shanghai Key Laboratory of All Solid-State Laser and Applied Techniques, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China. |
中文摘要 | 针对氨气(NH_3)和二氧化硫(SO_2)气体吸收谱线在196~214 nm波段区域存在谱线重叠的问题,在采用傅里叶变换的差分吸收光谱法测量气体浓度基础上,采用分波段方法,解决NH_3和SO_2特征频谱相互串扰对测量的影响,采用非线性修正方法,解决在SO_2高浓度情况下出现的非线性吸收对NH_3气体测量的影响,采用经验模态分解(EMD)降噪处理方法,提高信噪比,最终实现对NH_3和SO_2气体浓度的同时准确测量。实验结果显示,NH_3各个浓度测量误差均在0.15 mL/m~3以内,相对误差不超过1.5%,最低可探测浓度为1.5 mL/m~3;SO_2各个浓度测量误差均在2 mL/m~3以内,相对误差不超过1%,最低可探测浓度为16 mL/m~3。 |
英文摘要 | For the overlap of the absorption spectrum of NH_3 and SO_2 from 196 nm to 214 nm, based on differential optical absorption spectrometry and fast Fourier transform to measure concentration of gases, a method that detecting these two gases simultaneously at two wave length bands is proposed. The crosstalk effects between the characteristic spectrum of NH_3 and SO_2 are solved. The interference of SO_2 to NH_3 which is caused by the nonlinearity of the absorption of SO_2 with the increase of its concentration within 196~214 nm wavelength band is corrected, then the real concentration of NH_3 are obtained. The signal to noise ratio is improved by empirical mode decomposition (EMD) noise reduction method. The measurement error of NH_3 concentration is within 0.15 mL/m~3, ang the relative error is less than 1.5%. The detectable concentration limit is 1.5 mL/m~3. For SO_2, the measurement error is within 2 mL/m~3, and the relative error is less than 1%. The detectable concentration limit is 16 mL/m~3. |
收录类别 | EI |
原文出处 | http://www.opticsjournal.net |
语种 | 中文 |
内容类型 | 期刊论文 |
版本 | 出版稿 |
源URL | [http://ir.siom.ac.cn/handle/181231/13945] ![]() |
专题 | 上海光学精密机械研究所_空间激光信息技术研究中心 |
作者单位 | 1.郁敏捷, 中国科学院上海光学精密机械研究所, 上海市全固态激光器与应用技术重点实验室, 上海 201800, 中国. 2.刘铭晖, 中国科学院上海光学精密机械研究所, 上海市全固态激光器与应用技术重点实验室, 上海 201800, 中国. 3.董作人, 中国科学院上海光学精密机械研究所, 上海市全固态激光器与应用技术重点实验室, 上海 201800, 中国. 4.孙延光, 中国科学院上海光学精密机械研究所, 上海市全固态激光器与应用技术重点实验室, 上海 201800, 中国. 5.蔡海文, 中国科学院上海光学精密机械研究所, 上海市全固态激光器与应用技术重点实验室, 上海 201800, 中国. 6.魏芳, 中国科学院上海光学精密机械研究所, 上海市全固态激光器与应用技术重点实验室, 上海 201800, 中国. |
推荐引用方式 GB/T 7714 | 郁敏捷,刘铭晖,董作人,等. 基于傅里叶变换的差分吸收光谱法测量NH_3和SO_2浓度的实验研究[J]. 中国激光,2015,42(9):915001. |
APA | 郁敏捷,刘铭晖,董作人,孙延光,蔡海文,&魏芳.(2015).基于傅里叶变换的差分吸收光谱法测量NH_3和SO_2浓度的实验研究.中国激光,42(9),915001. |
MLA | 郁敏捷,et al."基于傅里叶变换的差分吸收光谱法测量NH_3和SO_2浓度的实验研究".中国激光 42.9(2015):915001. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论