中文摘要 | 在高速伪随机码调制和光子计数技术的激光测距系统中,采用不同的伪随机码,在光纤延时的方法下开展了基于不同伪随机码调制的测距实验并与M序列伪随机码进行对比。结果表明在相同的入射条件下,M序列伪随机码具有更好的信噪比和测距精度。搭建了实际测距平台并开展了室外测距实验,在10阶M序列伪随机码,1 GHz调制速率,发射光输出峰值功率12. 1 W,测量768.5 m远的目标时,得到3.2 cm的测距精度。 |
英文摘要 | Different pseudorandom codes are adapted in laser ranging system based on high modulation rate and photon counting technology. Ranging performance is compared and demonstrated between different pseudorandom codes and M sequence using fiber delay method of ranging experiments. Under the same incident condition, better signal of noise ratio and ranging accuracy are acquired when using M sequence. The actual ranging platform is established and ranging experiment outdoor is carried out. Ranging accuracy of 3. 2 cm is obtained when the laser transmit to a target which distance is about 768. 5 m under the condition of the transmitter peak power of 12.1 W, 10 order M pseudorandom sequence and 1 GHz modulation rate. |
收录类别 | EI |
语种 | 中文 |
内容类型 | 期刊论文 |
版本 | 出版稿 |
源URL | [http://ir.siom.ac.cn/handle/181231/13467] |
专题 | 上海光学精密机械研究所_空间激光信息技术研究中心 |
作者单位 | 1.杨芳, 中国科学院上海光学精密机械研究所, 中国科学院空间激光信息传输与探测技术重点实验室, 上海 201800, 中国. 2.张鑫, 中国科学院上海光学精密机械研究所, 中国科学院空间激光信息传输与探测技术重点实验室, 上海 201800, 中国. 3.贺岩, 中国科学院上海光学精密机械研究所, 中国科学院空间激光信息传输与探测技术重点实验室, 上海 201800, 中国. 4.陈卫标, 中国科学院上海光学精密机械研究所, 中国科学院空间激光信息传输与探测技术重点实验室, 上海 201800, 中国. |
推荐引用方式 GB/T 7714 | 杨芳,张鑫,贺岩,等. 基于不同伪随机码调制的光纤激光测距系统[J]. 中国激光,2014,41(6):614003. |
APA | 杨芳,张鑫,贺岩,&陈卫标.(2014).基于不同伪随机码调制的光纤激光测距系统.中国激光,41(6),614003. |
MLA | 杨芳,et al."基于不同伪随机码调制的光纤激光测距系统".中国激光 41.6(2014):614003. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论