Diagnostics of pulse contrast for petawatt laser in SGII | |
Ouyang, Xiaoping; Liu, Daizhong; Zhu, Baoqiang; Zhu, Jian; Zhu, Jianqiang | |
2015 | |
会议名称 | 3rd biennial conference on high power lasers for fusion research |
通讯作者 | ouyang, xp (reprint author), chinese acad sci, shanghai inst opt & fine mech, joint lab high power laser & phys, shanghai 201800, peoples r china. |
英文摘要 | pulse contrast is an important parameter for ultrafast pulses. it shall be 10(8) or higher in order to avoid effect from noise before main pulse. diagnostics with cross-correlation can achieve high temporal resolution such as similar to 7fs. cross-correlation has advantage in pulse contrast measurement than autocorrelation because it can distinguish noise before or after main pulse. high dynamic range is also essential in pulse contrast measurement. cross-correlation signal from a single shot is converted into a signal series through fiber array, which can be analyzed by a set of a pmt and an oscilloscope. noise from nonlinear crystal and scatter needs decrease to improve dynamic range. and pulse power is also discussed in pulse contrast experiments. time delay tau is generated by travel stage in measurement for repetition pulses. then energy instability will generate error in this measurement. in measurement for single shot pulse, time delay t is generated by slant angle of beams. the scanning procession is completed with thousands parts of beam section within a single shot, and error will generated from no uniformity in near field. performance test of pulse contrast measurement is introduced in subsequent sections. temporal resolution is testified by self-calibration. dynamic range is judged by a parallel flat. at last pulse contrast of petawatt laser is diagnosed by a single shot cross-correlator with high confidence. the ratio is 10(-6) at 50ps before main pulse, and 10(-4) at 10ps before main pulse. |
收录类别 | CPCI |
会议录 | high power lasers for fusion research iii
![]() |
会议录出版者 | spie-int soc optical engineering |
语种 | 英语 |
内容类型 | 会议论文 |
源URL | [http://ir.siom.ac.cn/handle/181231/17179] ![]() |
专题 | 上海光学精密机械研究所_高功率激光物理国家实验室 |
作者单位 | 1.[Ouyang, Xiaoping 2.Liu, Daizhong 3.Zhu, Baoqiang 4.Zhu, Jianqiang] Chinese Acad Sci, Shanghai Inst Opt & Fine Mech, Joint Lab High Power Laser & Phys, Shanghai 201800, Peoples R China 5.[Zhu, Jian] China Acad Engn Phys, Shanghai Inst Laser Plasma, Shanghai 201800, Peoples R China |
推荐引用方式 GB/T 7714 | Ouyang, Xiaoping,Liu, Daizhong,Zhu, Baoqiang,et al. Diagnostics of pulse contrast for petawatt laser in SGII[C]. 见:3rd biennial conference on high power lasers for fusion research. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论