Nitidine chloride-assisted bio-functionalization of reduced graphene oxide by bovine serum albumin for impedimetric immunosensing | |
Li, Y; Zhang, Z; Zhang, YT; Deng, DM; Luo, LQ; Han, BS; Fan, CH | |
刊名 | BIOSENSORS & BIOELECTRONICS
![]() |
2016 | |
卷号 | 79期号:-页码:536—542 |
关键词 | CARBON NANOTUBES CARCINOEMBRYONIC ANTIGEN IMPEDANCE SPECTROSCOPY GOLD NANOPARTICLES BIOMARKER DETECTION SIGNALING PATHWAY BINDING CANCER NANOCOMPOSITE IMMUNOASSAY |
ISSN号 | 0956-5663 |
通讯作者 | Luo, LQ (reprint author), Shanghai Univ, Coll Sci, Shanghai 200444, Peoples R China. ; Han, BS (reprint author), Shanghai Jiao Tong Univ, Shanghai Xinhua Hosp, Dept Surg, Shanghai 200092, Peoples R China. |
英文摘要 | A novel protocol of label-free electrochemical impedance immunosensor based on bovine serum albumin-nitidine chloride-reduced graphene oxide (BSA-NC-rGO) nanocomposite was proposed for quantitative determination of carcino-embryonic antigen (CEA). BSA was anchored to rGO via the aromatic plane of NC by pi-stacking interaction to realize bio-functionalization of rGO, and then gold nanoparticles (AuNPs) were electrodeposited onto the surface of BSA-NC-rGO nanocomposite. The morphology, conductivity and interaction of different nanocomposites were characterized by scanning electron microscopy, cyclic voltammetry, electrochemical impedance spectroscopy (EIS) and UV-vis spectrum. CEA monoclonal antibody (anti-CEA) was conjugated to AuNPs via gold-thiol chemistry to construct electrochemical immunosensing platform, and the specific immunoreaction between CEA and anti-CEA was monitored by EIS. Under optimum conditions, CEA could be quantified in a wide range of 0.1-200 ng mL(-1) (R=0.9948) with low detection limit of 0.067 ng mL(-1). The proposed immunosensor exhibited great potential for detecting blood samples. (C) 2015 Elsevier B.V. All rights reserved. |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000370309200075 |
内容类型 | 期刊论文 |
源URL | [http://ir.sinap.ac.cn/handle/331007/25786] ![]() |
专题 | 上海应用物理研究所_中科院上海应用物理研究所2011-2017年 |
推荐引用方式 GB/T 7714 | Li, Y,Zhang, Z,Zhang, YT,et al. Nitidine chloride-assisted bio-functionalization of reduced graphene oxide by bovine serum albumin for impedimetric immunosensing[J]. BIOSENSORS & BIOELECTRONICS,2016,79(-):536—542. |
APA | Li, Y.,Zhang, Z.,Zhang, YT.,Deng, DM.,Luo, LQ.,...&Fan, CH.(2016).Nitidine chloride-assisted bio-functionalization of reduced graphene oxide by bovine serum albumin for impedimetric immunosensing.BIOSENSORS & BIOELECTRONICS,79(-),536—542. |
MLA | Li, Y,et al."Nitidine chloride-assisted bio-functionalization of reduced graphene oxide by bovine serum albumin for impedimetric immunosensing".BIOSENSORS & BIOELECTRONICS 79.-(2016):536—542. |