Influence of ocular aberrations on contrast in retinal dark field imaging | |
Zhao, Junlei1,2,3; Dai, Yun1,2; Yang, Jinsheng1,2; Kang, Jian1,2,3; Xiao, Fei1,3; Zhang, Yudong1,2 | |
刊名 | Chinese Optics Letters
![]() |
2014 | |
卷号 | 12期号:SUPPL.1页码:S11002 |
ISSN号 | 16717694 |
通讯作者 | Zhang, Y. (hustoejunzuo@163.com) |
中文摘要 | The application of dark-field (DF) technique with adaptive optics for retinal imaging in vivo is presented to improve retinal imaging contrast. The influence on the imaging contrast introduced by dynamic ocular aberrations should be considered. The qualitative analysis of the influence is discussed. Detail simulation and quantitative analysis are presented. According to our simulation results, when residual aberrations are reduced to less than 5%, it has a little impact on the contrast of DF imaging; while, on increasing the aberrations up to 10%, the contrast of the DF imaging falls off sharply. © 2014 Chinese Optics Letters. |
英文摘要 | The application of dark-field (DF) technique with adaptive optics for retinal imaging in vivo is presented to improve retinal imaging contrast. The influence on the imaging contrast introduced by dynamic ocular aberrations should be considered. The qualitative analysis of the influence is discussed. Detail simulation and quantitative analysis are presented. According to our simulation results, when residual aberrations are reduced to less than 5%, it has a little impact on the contrast of DF imaging; while, on increasing the aberrations up to 10%, the contrast of the DF imaging falls off sharply. © 2014 Chinese Optics Letters. |
学科主题 | Optics - Physics |
收录类别 | SCI ; EI |
语种 | 英语 |
WOS记录号 | WOS:000353643700017 |
内容类型 | 期刊论文 |
源URL | [http://ir.ioe.ac.cn/handle/181551/6376] ![]() |
专题 | 光电技术研究所_自适应光学技术研究室(八室) |
作者单位 | 1.The Laboratory on Adaptive Optics, Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu 610209, China 2.The Key Laboratory on Adaptive Optics, Chinese Academy of Sciences, Chengdu 610209, China 3.University of Chinese Academy of Sciences, Beijing 100049, China |
推荐引用方式 GB/T 7714 | Zhao, Junlei,Dai, Yun,Yang, Jinsheng,et al. Influence of ocular aberrations on contrast in retinal dark field imaging[J]. Chinese Optics Letters,2014,12(SUPPL.1):S11002. |
APA | Zhao, Junlei,Dai, Yun,Yang, Jinsheng,Kang, Jian,Xiao, Fei,&Zhang, Yudong.(2014).Influence of ocular aberrations on contrast in retinal dark field imaging.Chinese Optics Letters,12(SUPPL.1),S11002. |
MLA | Zhao, Junlei,et al."Influence of ocular aberrations on contrast in retinal dark field imaging".Chinese Optics Letters 12.SUPPL.1(2014):S11002. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论