BEPC II wire scanner system
Sui YF(随艳峰); Wang L(汪林); Zhao Y(赵颖); Yue JH(岳军会); Li XP(李小平); Cao JS(曹建社); Ma L(马力); Sui, YF; Wang, L; Zhao, Y
刊名CHINESE PHYSICS C
2010
卷号34期号:10页码:1661-1664
关键词BEPC II beam instrument beam profile wire-scanner
通讯作者[Sui Yan-Feng ; Wang Lin ; Zhao Ying ; Yue Jun-Hui ; Li Xiao-Ping ; Cao Jian-She ; Ma Li] CAS, Inst High Energy Phys, Beijing 100049, Peoples R China ; [Sui Yan-Feng ; Li Xiao-Ping] Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China
英文摘要To monitor the beam profile at the end of the linac non-destructively, a wire scanner as a new diagnostic instrument was designed, manufactured and installed in 2007. Since then, several measurements have been carried out using this device. This paper describes the whole system of the wire scanner and the testing results.
学科主题Physics
类目[WOS]Physics, Nuclear ; Physics, Particles & Fields
研究领域[WOS]Physics
原文出处SCI
语种英语
WOS记录号WOS:000282531300021
内容类型期刊论文
源URL[http://ir.ihep.ac.cn/handle/311005/239463]  
专题高能物理研究所_加速器中心
作者单位中国科学院高能物理研究所
推荐引用方式
GB/T 7714
Sui YF,Wang L,Zhao Y,et al. BEPC II wire scanner system[J]. CHINESE PHYSICS C,2010,34(10):1661-1664.
APA 随艳峰.,汪林.,赵颖.,岳军会.,李小平.,...&Ma, L.(2010).BEPC II wire scanner system.CHINESE PHYSICS C,34(10),1661-1664.