The calibration of cellphone camera-based colorimetric sensor array and its application in the determination of glucose in urine | |
Jia, Ming-Yan1,3; Wu, Qiong-Shui2; Li, Hui1; Zhang, Yu1; Guan, Ya-Feng1; Feng, Liang1 | |
刊名 | biosensors & bioelectronics |
2015-12-15 | |
卷号 | 74页码:1029-1037 |
关键词 | Calibration Cellphone camera Colorimetric sensor array Glucose Urine |
英文摘要 | in this work, a novel approach that can calibrate the colors obtained with a cellphone camera was proposed for the colorimetric sensor array. the variations of ambient light conditions, imaging positions and even cellphone brands could all be compensated via taking the black and white backgrounds of the sensor array as references, thereby yielding accurate measurements. the proposed calibration approach was successfully applied to the detection of glucose in urine by a colorimetric sensor array. snapshots of the glucose sensor array by a cellphone camera were calibrated by the proposed compensation method and the urine samples at different glucose concentrations were well discriminated with no confusion after a hierarchical clustering analysis. (c) 2015 elsevier b.v. all rights reserved. |
WOS标题词 | science & technology ; life sciences & biomedicine ; physical sciences |
类目[WOS] | biophysics ; biotechnology & applied microbiology ; chemistry, analytical ; electrochemistry ; nanoscience & nanotechnology |
研究领域[WOS] | biophysics ; biotechnology & applied microbiology ; chemistry ; electrochemistry ; science & technology - other topics |
关键词[WOS] | microfluidic devices ; optoelectronic nose ; quantum dots ; smartphone ; discrimination ; diagnostics ; oxidase |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000360772800139 |
公开日期 | 2016-05-09 |
内容类型 | 期刊论文 |
源URL | [http://cas-ir.dicp.ac.cn/handle/321008/146533] |
专题 | 大连化学物理研究所_中国科学院大连化学物理研究所 |
作者单位 | 1.Chinese Acad Sci, Dalian Inst Chem Phys, Key Lab Separat Sci Analyt Chem, Dalian 116023, Peoples R China 2.Wuhan Univ, Elect Informat Sch, Wuhan 430072, Peoples R China 3.Univ Chinese Acad Sci, Beijing 100049, Peoples R China |
推荐引用方式 GB/T 7714 | Jia, Ming-Yan,Wu, Qiong-Shui,Li, Hui,et al. The calibration of cellphone camera-based colorimetric sensor array and its application in the determination of glucose in urine[J]. biosensors & bioelectronics,2015,74:1029-1037. |
APA | Jia, Ming-Yan,Wu, Qiong-Shui,Li, Hui,Zhang, Yu,Guan, Ya-Feng,&Feng, Liang.(2015).The calibration of cellphone camera-based colorimetric sensor array and its application in the determination of glucose in urine.biosensors & bioelectronics,74,1029-1037. |
MLA | Jia, Ming-Yan,et al."The calibration of cellphone camera-based colorimetric sensor array and its application in the determination of glucose in urine".biosensors & bioelectronics 74(2015):1029-1037. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论