A study of time over threshold (TOT) technique for plastic scintillator counter | |
Wu JJ(吴金杰); Heng YK(衡月昆); Sun ZJ(孙志嘉); Wu C(吴冲); Zhao YD(赵玉达); Yang GA(杨桂安); Jiang CH(姜春华) | |
刊名 | 中国物理C |
2008 | |
期号 | 3页码:186-190 |
关键词 | scintillator counter time over threshold(TOT) charge measurement relative resolution |
通讯作者 | 吴金杰 |
英文摘要 | A new charge measurement method,time over threshold(TOT),has been used in some gas detectors lately.Here TOT is studied for TOF system,made of plastic scintillator counter,which can simplify the electronics of the system.The signal characteristics are measured and analyzed with a high quality osc... |
公开日期 | 2016-02-26 |
内容类型 | 期刊论文 |
源URL | [http://ir.ihep.ac.cn/handle/311005/219111] |
专题 | 高能物理研究所_实验物理中心 |
推荐引用方式 GB/T 7714 | Wu JJ,Heng YK,Sun ZJ,et al. A study of time over threshold (TOT) technique for plastic scintillator counter[J]. 中国物理C,2008(3):186-190. |
APA | 吴金杰.,衡月昆.,孙志嘉.,吴冲.,赵玉达.,...&姜春华.(2008).A study of time over threshold (TOT) technique for plastic scintillator counter.中国物理C(3),186-190. |
MLA | 吴金杰,et al."A study of time over threshold (TOT) technique for plastic scintillator counter".中国物理C .3(2008):186-190. |
个性服务 |