Low temperature testing and neutron irradiation of a swept charge device on board the HXMT satellite
Wang YS(王于仨); Chen Y(陈勇); Xu YP(徐玉朋); Yang YJ(杨彦佶); Cui WW(崔苇苇); Li MS(李茂顺); Liu XY(刘晓艳); Wang J(王娟); Han DW(韩大炜); Chen TX(陈田祥)
刊名Chinese Physics C
2012
期号10页码:991-995
关键词SCD HXMT energy resolution readout noise neutron irradiation
通讯作者王于仨
英文摘要We present the low temperature testing of an SCD detector, investigating its performance such as readout noise, energy resolution at 5.9 keV and dark current. The SCD's performance is closely related to temperature, and the temperature range of 80℃ to 50℃ is the best choice, where the FWHM at 5.9 ke...
公开日期2016-02-25
内容类型期刊论文
源URL[http://ir.ihep.ac.cn/handle/311005/218042]  
专题高能物理研究所_粒子天体物理中心
推荐引用方式
GB/T 7714
Wang YS,Chen Y,Xu YP,et al. Low temperature testing and neutron irradiation of a swept charge device on board the HXMT satellite[J]. Chinese Physics C,2012(10):991-995.
APA 王于仨.,陈勇.,徐玉朋.,杨彦佶.,崔苇苇.,...&张子良.(2012).Low temperature testing and neutron irradiation of a swept charge device on board the HXMT satellite.Chinese Physics C(10),991-995.
MLA 王于仨,et al."Low temperature testing and neutron irradiation of a swept charge device on board the HXMT satellite".Chinese Physics C .10(2012):991-995.