A novel calibration method for Acoustic Vector Sensor
Zhang Y(张瑶); Gu HT(谷海涛); Li GN(李冠男)
2016
会议名称OCEANS 2016 MTS/IEEE Monterey
会议日期September 19-23, 2016
会议地点Monterey, Canada
关键词Acoustic Vector Sensor Phase Instantaneous Correlation Integral SNR
页码1-4
通讯作者张瑶
中文摘要The Acoustic Vector Sensor can measure both pressure and particle velocity information of acoustic field at a point in space. By using the acoustic pressure and particle velocity information, a single AVS can get the unbiased estimation of target’s bearing. But when the phase of each channel is inconsistent, the estimation precision will be badly affected. In order to solve this problem, this paper uses the instantaneous correlation integral as a preprocessing algorithm. After the instantaneous correlation integral, the phase of each channel becomes the same, and the signal-to-noise (SNR) ratio of the input signal is improved, which can guarantee the effectiveness of target bearing estimation. Theoretical analysis and simulation results verify the effectiveness of this method.
收录类别EI
产权排序1
会议录OCEANS 2016 MTS/IEEE Monterey
会议录出版者IEEE
会议录出版地New York
语种英语
ISBN号978-1-5090-1527-6
内容类型会议论文
源URL[http://ir.sia.cn/handle/173321/17341]  
专题沈阳自动化研究所_海洋信息技术装备中心
推荐引用方式
GB/T 7714
Zhang Y,Gu HT,Li GN. A novel calibration method for Acoustic Vector Sensor[C]. 见:OCEANS 2016 MTS/IEEE Monterey. Monterey, Canada. September 19-23, 2016.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace