CORC  > 自动化研究所  > 中国科学院自动化研究所  > 09年以前成果
Method for calibrating cameras with large lens distortion
Xu, D; Li, YF; Tan, M
刊名OPTICAL ENGINEERING
2006-04-01
卷号45期号:4
关键词camera calibration planar pattern radial distortion distortion correction Hough transform
英文摘要A new calibration method is proposed for calibrating cameras with large lens distortion, using a planar grid pattern. The distortions are adjusted with an iterative algorithm. When the points on each curve in the image of the grid pattern are fitted with a linear equation in the image space, the distortion correction factors are determined. The camera's optical center is obtained through a Hough transform. Then, a group of linear equations and a cubic equation are established in the corrected image space. The remaining parameters of the camera are then deduced. Only one view of a planar grid pattern is needed for this method. The experimental results verify the effectiveness of the proposed method. (c) 2006 Society of Photo-Optical Instrumentation Engineers.
WOS标题词Science & Technology ; Physical Sciences
类目[WOS]Optics
研究领域[WOS]Optics
收录类别SCI
语种英语
WOS记录号WOS:000237622200014
内容类型期刊论文
源URL[http://ir.ia.ac.cn/handle/173211/9367]  
专题自动化研究所_09年以前成果
作者单位1.City Univ Hong Kong, Dept Mfg Engn & Engn Management, Kowloon, Hong Kong, Peoples R China
2.Chinese Acad Sci, Inst Automat, Key Lab Complex Syst & Intelligence Sci, Beijing 100080, Peoples R China
推荐引用方式
GB/T 7714
Xu, D,Li, YF,Tan, M. Method for calibrating cameras with large lens distortion[J]. OPTICAL ENGINEERING,2006,45(4).
APA Xu, D,Li, YF,&Tan, M.(2006).Method for calibrating cameras with large lens distortion.OPTICAL ENGINEERING,45(4).
MLA Xu, D,et al."Method for calibrating cameras with large lens distortion".OPTICAL ENGINEERING 45.4(2006).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace