Latest advances of X-ray imaging and biomedical applications beamline at SSRF | |
Xie, HL; Deng, B; Du, GH; Fu, YN; Chen, RC; Zhou, GZ; Ren, YQ; Wang, YD; Xue, YL; Peng, GY | |
刊名 | NUCLEAR SCIENCE AND TECHNIQUES |
2015 | |
卷号 | 26期号:2页码:— |
关键词 | FLUORESCENCE COMPUTED-TOMOGRAPHY CONTROLLED-RELEASE KINETICS OSMOTIC PUMP TABLETS SYNCHROTRON-RADIATION IN-SITU DIRECTIONAL SOLIDIFICATION SOLDERING REACTION BONE REGENERATION GROWTH-BEHAVIOR PHASE RETRIEVAL |
英文摘要 | On May 6, 2009, the X-ray imaging and biomedical application beamline (BL13W1) at Shanghai Synchrotron Radiation Facility (SSRF) officially opened to users, with 8-72.5 keV X-rays. The experimental station is equipped with four sets of X-ray CCD detectors of different pixel size (0.19-24 pm) for on-line phase-contrast imaging and micro-CT imaging with 0.8 mu m spatial resolution and 1 ms temporal resolution. An in vivo micro-CT experiment for a living insect was realized in 4s. An X-ray fluorescence detector is equipped for X-ray fluorescence mapping imaging and X-ray fluorescence micro-CT imaging with 50 pm spatial resolution. In order to meet different requirements from the users, several experimental methods, such as X-ray spiral micro-CT, Xray local micro-CT, X-ray fast micro-CT, X-ray grating-based differential micro-CT, X-ray fluorescence micro-CT and X-ray quantitative micro-CT have been developed, and nearly 60 papers related to those developments for this beamline have been published. Moreover, the beamline has realized the remote fast CT reconstruction, providing a great convenience for the users to process experimental data at their offices. As of August 2014, the beamline has offered the user beamtime of (23 145 h), from which 232 user papers have been published, including 151 SCI papers and 55 papers with SCI impact factor > 3. The quantity and quality of the user paper outcome keep a steady increase. Some typical user experimental results are introduced. |
收录类别 | SCI |
语种 | 英语 |
公开日期 | 2015-12-24 |
内容类型 | 期刊论文 |
源URL | [http://ir.sinap.ac.cn/handle/331007/24494] |
专题 | 上海应用物理研究所_中科院上海应用物理研究所2011-2017年 |
推荐引用方式 GB/T 7714 | Xie, HL,Deng, B,Du, GH,et al. Latest advances of X-ray imaging and biomedical applications beamline at SSRF[J]. NUCLEAR SCIENCE AND TECHNIQUES,2015,26(2):—. |
APA | Xie, HL.,Deng, B.,Du, GH.,Fu, YN.,Chen, RC.,...&Xiao, TQ.(2015).Latest advances of X-ray imaging and biomedical applications beamline at SSRF.NUCLEAR SCIENCE AND TECHNIQUES,26(2),—. |
MLA | Xie, HL,et al."Latest advances of X-ray imaging and biomedical applications beamline at SSRF".NUCLEAR SCIENCE AND TECHNIQUES 26.2(2015):—. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论